Schaltbau CO4 series changeover unit

Schaltbau CO4 high-voltage changeover unit for cross-border rail vehicles

High-voltage changeover unit CO4 series

High-voltage changeover units of the CO4 series are switching devices for load-free configuration of electrical loads. The new 6-position devices are now more powerful – the cam switchgear configures faster and the switching chambers can carry higher currents. Changeover devices are needed for voltage configuration for railway vehicles in cross-border traffic with changing supply voltages. Here, the changeover unit is the link between the train busbar and the electrical consumers, e.g. power supply systems and heating registers.

Features

Wide power range

UIC voltages up to 3,600 volts, with reinforced insulation 5,000 volts; continuous thermal currents up to 100 amps. Load-free adaptation of electrical configurations to
different train busbar systems according to UIC 550.

6 switching positions

6 control inputs for 6 pre-configured
positions, controlled via a motor-operated cam controller.

Modularity

Cam switchgear with 2 to 10 switching chambers* including ready-to-use connection configuration; customerspecific defined switching programmes as well as many switching programmes of European railway operators available.

* others upon request

Standards

Tested to railway standard EN 60077-1,EN 60077-2,
UIC 550 as well as EN 50124-1 and EN 50163.

Specifications

Switching gear
Number of switching chambers 2-4-6-8-10, others upon request
Control 6 control inputs, 6 pre-configured positions
Drive Cam gear, electric motor
Contact system per switching chamber
Type of voltage DC, AC (f ≥ 60 Hz)
Nominal voltage Un 3,000 V
Rated operating voltage Ue 3,600 V @ PD3, OV3
5,000 V @ PD2, OV2
Rated insulation voltage UNm 3,600 V @ PD3, OV3
5,000 V @ PD2, OV2
Rated impulse withstand voltage UNi 25 kV
Pollution degree PD2, PD3
Overvoltage category OV2, OV3
Conv. thermal current Ith 100 A @ 70° C
Drive
Control voltage US 24 … 110 V DC
Control voltage tolerance 0.7 … 1.25 x Us
Power dissipation 20 W during changeover operation, otherwise none
General data
Vibration, Shock Category 1, class B
Mechanical endurance 125,000 operating cycles
Mounting orientation horizontal, vertical (do not mount upside down)
Temperature range –40° C … +85° C
Weight approx. 9.5 kg, device with 10 switching chambers

Related Downloads

Flyer F180
CO4 – High-voltage changeover unit for rail vehicles
Safety instructions electrics for rolling stock
Equipment for driver’s cab and passenger use, high-voltage equipment

/en/products/electrics-for-rolling-stock/thank-you-kopie/CO4 – High-voltage changeover unitElectrics for rolling stock

Your quick contact to us!

If you have any questions, suggestions or other concerns, please let us know. Please fill out our short contact form.